Authorized use
2. AUTHORIZED USE
Unauthorized use of the device Type 6013 may be dangerous
to people, nearby equipment and the environment.
The device is used is used exclusively as a solenoid valve for media
permitted according to the data sheet and for use in Explosion
group II, Category 2G or 2D and Temperature class T4, T5 or T6
(see specifications on the approval plate).
The device may be used only for the applications designated in
chapter “5. Application conditions of the devices” and in conjunc-
tion with third-party devices and components recommended and
authorized by Bürkert.
The applied protection class is encapsulation EX “m” for coils with
cable connection or encapsulation with increased safety EX “em”
for coils with terminal box.
Observe the requirements of EN 61241-0/-1 e.g. with reference
to dust deposits and temperatures.
The solenoid coil AC10 is used to activate valves which control
the gaseous or liquid media. The device is part of a closed sys-
tem and may also be used in gasoline pumps to control gasoline
as Category 2.
The faultless and reliable operation of the system assumes cor-
rect transportation, correct storage and installation as well as
careful operation and maintenance. Any other use is regarded as
unauthorized. Bürkert is not liable for any resulting damage. The
user alone bears the risk.
Only use the device for its intended purpose.
2.1. Restrictions
If exporting the system/device, observe any existing restrictions.
2.2. EX approval
The EX approval is only valid if the modules and components autho-
rized by Bürkert are used as described in these operating instructions.
Type 0742 may be used only in combination with the additional com-
ponents released by Bürkert, otherwise the EX approval will be voided!
If any unauthorized changes are made to the device, modules or com-
ponents, the EX approval will also be voided.