Burkert Type 8625 Manuel d'utilisateur Page 12

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 118
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 11
10 - 8625-2 Standard
english
M12 (4-pole): Supply voltage and standard signal for setpoint
Configuration:
1 PT100 supply (0.5 mA)
3 GND
4 Temperature input PT100
* wire colours when using standard cables
with M8 plug (3-pole)
1 (brown)*4 (black)
3 (blue) 2 (white)
Configuration:
1 24 V DC supply voltage
2 Standard signal input, external setpoint
3 GND external setpoint
4 GND supply voltage
* wire colours when using standard cables
with M12 plug (4-pole)
M8 (PT100-input):
1 (brown)
4 (black)
3 (blue)*
5.3 Connection configuration of temperature controller
type 8625-2
Fig.: Connections on temperature controller type 8625-2
M8, 3-pole
PT100 input
M12, 4-pole
Supply voltage
and standard
signal input
External setpoint
Vue de la page 11