13
Technical data
7.4.1. Temperature ranges
Actuator
size
[mm]
Actuator
material
Medium
Environ-
ment
2)
Seat seal
steel / steel
Seat seal
PTFE / steel
ø 50
PPS
-10 -
+185 °C
-10 -
+130 °C
0 -
+60 °C
3)
0 -
+100 °C
4)
ø 70
ø 90
ø 130
Tab. 2: Temperature ranges
2)
If a pilot valve/control unit is used, the max. ambient
temperature is +55 °C.
The angle-seat control valve is suitable for steam
sterilization.
3) Pilot air ports with push-in connector
4) Pilot air ports with threaded bushing.
7.4.2. Control medium
In conjunction with pneumatic control units (positioner or process
controllers), pilot air according to DIN ISO 8573-1 must be used:
Class 3 (for water content)
Class 5 (for dust and oil content).
The specification is described in detail in the operating
instructions of the respective positioner / process controller
in the chapter entitled “Technical Data”.
7.4.3. Pressure ranges
Pilot pressure range
5)
on controlled operation
Actuator
size
Orifice DN
[mm]
Pilot pressure range
5)
[bar]
CFA CFB
ø 50 mm 15 – 25 3,4 – 5,5 3,3 – 5,1
ø 70 mm 15 – 32 2,6 – 5,5 2,6 – 5,2
ø 90 mm 25 – 50 3,3 – 5,5 1,8 – 2,5
ø 130 mm
40 – 50 3,3 – 5,6 1,9 – 2,7
65 4,6 – 5,6 1,9 – 2,7
Tab. 3: Pilot pressure range on controlled operation
5) To ensure reliable operation with pneumatic control
units (positioner or process controller), observe the
permitted minimum and maximum pilot pressure!
english